الخميس، 11 يوليو 2013

all ophthalmology instruments list

This is a list of intruments used in ophthalmology clinical and surgical and its function in brief let's go:
  • Toric Marker
to mark 0 to 180 degree reference mark for Toric IOL implant 
  • Pre-chopper
to chop lens into pieces before implantation new lens and reduce phaco time
  • Spectacles (glasses)
to correct refractive errors of the eye; not invasive
  • Contact lenses
to correct refractive errors of the eye; a little invasive
  • Phoropter
used in refraction testing
  • Tonometers
used to determine the intraoccular pressure (IOP) - useful in glaucoma; vide link for various types of tonometers.
  • Speculum: 
   to keep the eyes open during any operation
  • Universal eye speculum
heavy instrument and can not keep eyelashes out of the operating field
•Guarded eye speculum (left and right) 
 heavy instrument but can keep eyelashes out of the operating field with its "guard" and hence left or right ones are required
•Wire Speculum 
 to keep the eyes open during any operation; light wire instrument
Needle holders:
holding the needle in position while applying sutures
•Silcock's needle holder 
  has a catch and is used for heavier gauge needles; used mainly for skin, muscle and corneal incisions
•Arruga's needle holder  
has a catch (lock) and is used for heavier gauge needles (thicker than 6-0); used mainly for skin, muscle and corneal incisions
•Barraquer's needle holder   
 small instrument with a spring action with or without a catch used for finer gauge needles (5-0 or finer); used mainly for intraoccular incisions
Forceps:
to hold anything
•Artery forceps (haemostat)
medium sized, with a serrated tip and a catch; used to hold bleeding vessels and compress them in order to make them stop bleeding and also to hold or crush structures.
•Fixation forceps  
  has a few teeth at the tip; for holding structures and restricting their movement or to hold small swabs
•Plain dissecting forceps 
    blunt untoothed with a serrated tip; for holding structures and restricting their movement or to hold small swabs
•Iris forceps     
 fine tipped (straight or otherwise) with small teeth; to hold the iris tissue during procedures
•Elschnig's intracapsular forceps 
  fine untoothed forceps for holding tissue, swabs, sutures, etc.; removing things like clots, capsule fragments, lens, etc.; used in cataract surgery
•Arruga's intracapsular forceps 
 fine untoothed forceps holding tissue, swabs, sutures, etc.; removing things like clots, capsule fragments, lens, etc.; used in cataract surgery
•Colibri forceps 
 fine toothed forceps for holding flaps of cornea or sclera and rarely the iris
•Saint Martin's forceps 
  holding flaps of cornea or sclera and rarely the iris
•Superior rectus holding forceps           
 specially curved (to fit into the orbit of the eye) forceps for catching hold of the muscle bellies of the intraorbital muscles and sutures
•Suture tier forceps       
fine limbed untoothed forceps to hold fine sutures or hairs
•Capsulotomy forceps   
 to tear the anterior capsule of the lens during cataract surgery
•Disc holding forceps      
used in glaucoma surgery (obsolete)
•Capsulorhexis forceps 
 fine sharp-tipped untoothed forceps for doing a continuous curvilinear incision and removal of the anterior capsule of the lens ("continuous curvilinear capsulorhexis - ccc")
•MacPherson's forceps  
fine sharp-tipped untoothed forceps with an angulation for holding parts of the lens, the intraocular lens, 10-0 (very fine) sutures, etc.
•Chalazion forceps (clamp)      
  self-retaining with discoid ends; used to hold and prevent a chalazion from bleeding during its surgery
Diamond knife
used to perform microincisions on the cornea in the Radial keratotomy and Mini Asymmetric Radial Keratotomy (M.A.R.K.)
•Epilation forceps (Cilia forceps)         
   stout flat-ended blunt forceps with a thickened end to remove eyelashes
•Entropion forceps       
 self-retaining with big discoid ends used to hold and prevent an entropion from bleeding during its surgery
Chalazion scoop
to remove the granulation tissue from a chalazion during surgery
Entropion clamp           
 right and left varieties exist; large clamp with two limbs; self-retaining with big discoid ends used to hold and prevent an entropion from bleeding during its surgery
Nettleship's punctum dilator    
 to dilate the lacrimal punctum of the lacrimal apparatus of the eye for syringing or operations
Cystitome        
 a 26 gauge needle bent twice used for incising the anterior capsule of the lens in lens extraction
Wire vectis       
 a loop of wire attached to a stack used to extract cataract affected lenses
Irrigating vectis  
a small hollow instrument with a used to introduce fluid into the anterior chamber to raise its pressure to aid cataract extraction
Canula
used to carry fluid
•Irrigation-aspiration two-way canula    
 effectively two small canulae fitted together, one to introduce fluid and the other to extract the cortical materials, blood, etc. in eye operations
•Lacrimal canula           
 small curved canula the size of a syringe needle used to introduce fluids or drugs into the nasolacrimal passage to test its patency or during surgery (dacrocystography, dacrocystectomy, dacryocystorhinostomy(DCR), etc.
Lang's lacrimal dissector with scoop      
 for blunt dissections and cleaning during operations like dacryocystorhinostomy
Rougine
dissection of lacrimal sac
Retractor
to pull and hold overlying tissue out of the operating field
•Muller's self retaining adjustable haemostatic retractor self retaining haemostatic
•Cat's paw retractor 
•Desmarre's lid retractor      
 specially for noncooperative patients and to see the fornices (see human eye)
Bone punch    
  to fracture pieces from a thin bone in facial surgery and during operations like dacryocystorhinostomy
Evisceration spoon or scoop    
  removing all the contents of the eyeball during evisceration (complete removal of all structures within the eye in diseases like endophthalmitis
Lid plate 
 flat large instrument that has a groove and is placed between the lid and globe of the eye to provide a solid support for eyelid surgery
  • Hammer, chisel and bone gouge bone cutting and shaping
  • Bowmen's discission needle 
 microsurgery of the lens capsule
  • Knives
to cut structures
•Surgical scalpel with small blades 
 general purpose instrument
•von Graefe's cataract knife      
 cutting out of the anterior chamber from the inside through the limbus
•Tookes' knife (Sclero-corneal splitter)  
 making sclerocorneal tunnels in "small incision cataract surgery (SICS)" and keratoplasty
•Crescent knife (Sclero-corneal splitter) 
  making sclerocorneal tunnels in "small incision cataract surgery"
•Angular keratome 
 making sclerocorneal tunnels in "small incision cataract surgery"; larger one used to increase the size of the incision
•Side-port blade 
making sclerocorneal "side port" (a secondary tunnel) tunnels in "small incision cataract surgery"
•Beer's knife
incise the conjunctiva or the eyelid skin
•Keratotome   
 small triangular blade with two sharp edges used to incise the limbus (sclerocorneal junction)
•Zeigler's knife 
 very tiny knife for intaoccular maneuvers specially when space is less
  • Scissors 
•Conjunctival sac scissors
flat small curved scissors to cut the conjunctive
•Corneal spring scissors 
 medium spring-open used to cut the external side of the cornea, fine sutures; iris, etc.
•de' Wecker's iris scissors
small slender spring-open scissors for intraoccular maneuvers (iris and deeper and more delicate structures); has two wings to operate it and one sharp and one blunt blade.
•Vannas' scissors 
 small slender spring-open scissors for intraoccular maneuvers (iris and deeper and more delicate structures); has two wings to operate it and one sharp and one blunt blade.
•Enucleation scissors 
 thick scissors used to cut the optic nerve in enucleation operation
  • Bowman's lacrimal probe  
 probing the nasolacrimal duct
  • Lens expressor 
 used to force out the lens in extracapsular or intracapsular cataract extraction
  • McNamar's spoon 
 used to force out the lens in intracapsular cataract extraction
  • Iris repositor two limbed instrument used to remove the iris during posterior chamber maneuvers
  • Sinsky's hook intraocular lens dialler
angulated round hook with a handle used in insertion of an intraocular lens
Strabismus hook
muscle hook or squint hook; sharp tip or knobbed tip; used in squint surgery
Foreign body spud and needle  Spud
  to remove superficial and needle for the deep foreign bodies in the eye
Elliot's trephine with handle 
 used in corneal donation (eye donation) to cut out the cornea in a circular fashion
Castroveijo's calipers
  various measurements are taken
Castroveijo's corneal trephine   
 used in corneal donation (eye donation) to cut out the cornea in a circular fashion
Pin-hole          
 testing visual acuity
Red green goggles  
(red - right side & green - left side) used in Worth 4 dot test, diplopia testing
Prisms
to measure the degree of squints; in other instruments; refractive correction; etc.
Placido's disc    
 to assess the condition of the corneal surface
Retinoscope
objective determination of refractive error and for looking inside the eye
Loupe   used ot search for magnified examination of the anterior segment of the eye (uniocular or binocular)
Jackson's cross cylinder used to check the power and axis of a cylindrical lens
Maddox rod     used to test for latent squint and retinal function
Refraction box  has lenses of different powers for refraction testing
Slit lamp bio microscope
used for examining the anteriorly placed structures the eye; vide link
Charts for vision
-
•Distant vision
to determine visual acuity of distant vision
••Snellen's distant vision chart
-do-; for those who can read in English
••Regional language charts        -do-; for those who can read in their local language
••E Chart
-do-; for those who can not read
••Landolt's broken ring chart
-do-; for those who can not read
••Toys pr picture chart   -do-; for children
•Near vision
-do-; to determine visual acuity of near vision
••Jager's chart   -do-
••Printer's types of N series       -do-
••Snellen's near chart (1/17th reduction of distant chart)           -do-; standard chart of alphabets; vide link
•Colour vision:
to test colour vision
••Ishihara's chart
to determine the type of colour blondness
Stenopaeic slit
detection of axis of the cylindrical (astigmatism) power of the eye; glaucoma testing
Implants
-
•Intraocular lens
prosthetic lenses implanted after lens (anatomy) removal
•Artificial eyes   as non-functional cosmetic implants into the eye socket
Blade breaker
to break disposable blade after use to prevent reuse
Thermo-cautery
to coagulate blood vessels and prevent haemorrhage
Cryoprobe
to freeze and extract the lens
Yttrium aluminium garnet laser (YAG laser)
to correct posterior capsular opacification (specially after removal of a cataract, if required), peripheral iridotomy, retinal surgery, laser-assisted sub-epithelial keratectomy (LASEK) etc.
Electrolysis
used for permanent hair removal
Electrocautery
for electrosurgery
Phacoemulsification
used for extraction of a cataract affected lens after emulsifying it using a high frequency (energy) ultrasound probe

ليست هناك تعليقات: